Sale on Ophthalmic Equipment - Starting from 16 November!
In Switzerland, medical devices need no official authorisation, but a maker based abroad must name a Swiss authorised representative (CH-REP), and labels must be in the three official languages unless strict conditions are met. Our quotes for Switzerland set out the CH-REP, the label texts and freight via Basel or Zurich.
In Switzerland, the Medical Devices Ordinance of 2020 sets the rules and incorporates much of EU regulation by reference. Swissmedic is the authority, but medical devices in Switzerland go through no official authorisation, as its role is market surveillance. Swissmedic says CE-marked devices may in principle be placed on the Swiss market. A maker based outside Switzerland, including the EU or the UK, needs a Swiss authorised representative, the CH-REP, named on the label. So a quote for Switzerland starts with the CH-REP and the label text.
MediGear, a medical equipment distributor registered in England and Wales, handles each request from Switzerland. Buyers in the Swiss healthcare system get the same quotes, export documents and freight as buyers in more than 80 countries. The makers we approach for Swiss orders must already name a CH-REP, because we cannot act as one. Your medical technology team sees the quote only once the points below are settled. Requests start on the buyer's page, with no account to open.
Healthcare in Switzerland is a cantonal matter under the constitution, so we quote for:
Federal buying follows the Public Procurement Act, and cantons and communes follow the intercantonal agreement of 2019. Each canton runs health care in Basel, Bern and Geneva, so quotes go to the hospital concerned. Tenders are published on SIMAP, the joint platform of the Confederation, cantons and communes. At USZ, shell construction of the new Campus Mitte has run since 2025, with operations planned for 2031. Inselspital's eye clinic moved into the new Marie-Colinet-Haus in September 2026. A practice that buys just one unit gets the same written quote.
Before a device goes on the market, a Swiss importer checks the CE marking, the declaration of conformity, the CH-REP, the labelling and the UDI. Its name and address then appear on the device, the packaging, or an accompanying document. Importers and CH-REPs register with Swissmedic for a CHRN before they first place a device on the market, and distributors of medical devices cannot register. Since 1 July 2026, Swiss manufacturers and CH-REPs must also register devices in swissdamed, with a transition to 31 December 2026.
A health professional who uses a device from abroad directly, without placing it on the market, is responsible for its conformity. Our part ends with the quote and the freight to the port or airport you name. The importer, CH-REP and registration roles belong to Swiss firms, not to us, and so does the distribution of medical devices in Switzerland. Each quote names the CH-REP the maker uses and lists the unit's certificates, without giving regulatory advice.
Setting up and operating a medical X-ray system needs a licence from the FOPH, the Federal Office of Public Health. The operator applies before installation, with radiation-protection plans for the room and shielding calculations. Without that licence, the supplying firm may not install or hand over the system. A licence runs for 10 years, and it ends when the practice changes hands or moves. Firms in Switzerland that trade in, rent, install, or test X-ray systems need their own FOPH licence. Swiss diagnostic imaging with X-ray therefore starts with the FOPH licence.
Under the X-ray Ordinance, the supplier runs an acceptance test on the whole system before handover and sets reference values for later constancy tests. The operator then performs constancy tests and maintains he system. An FOPH-licensed firm performs a state check after each maintenance, and the results go to the FOPH. For X-ray systems in Switzerland, minimum state-check intervals are yearly for CT and mammography, every three years for interventional radiology and every six years for standard radiography and dental units.
Our questions to the manufacturer for a Swiss site:
The maker answers in writing before we quote, since the importer's checks and the FOPH licence both refer to the exact unit.
Swiss customs, the BAZG, lets a firm declare its imports itself or through a forwarder, courier or customs agency. Passar is replacing e-dec, and the last e-dec import declaration can be made on 30 September 2027. Papers that travel with the goods:
BAFU, the Federal Office for the Environment, applies ISPM 15 to wood packaging from countries outside the EU. Crates from the UK must therefore carry the mark. Some goods groups in wood packaging from third states must also be pre-notified two days before import, and we could not confirm whether medical equipment is one of them. For that reason, makers are asked to ship in heat-treated, stamped crates.
At the Basel terminal or Zurich airport, the goods pass to your declarant, who lodges the import declaration with the BAZG. Onward transport is yours or your Swiss partner's, and lorries over 3.5 tonnes may not run at night (22:00 to 05:00) or on Sundays.
An eye clinic in Lucerne could order just one slit lamp, since we quote catalogue lines per unit. New practices can start from clinic setup, and physiotherapists can browse Physiotherapy and Wellness Equipment. Our refurbished range can serve Switzerland, since no Swiss ban on used or refurbished devices turned up. A hospital that wants a refurbished system can request a quote the same way. For X-ray machines, Swiss X-ray rules do not distinguish between new and used systems, so the acceptance test and the FOPH licence apply either way. Whoever fully refurbishes a device and markets it under their own name counts as its manufacturer, including an X-ray manufacturer, and used single-use devices may not be reprocessed or supplied after reprocessing abroad. Your request may list lab equipment next to medical devices, so mark which items are devices. Laboratory equipment that is not a medical device falls outside the Swiss device rules, which cover devices only.
For Swiss buyers, this page is background reading only. It offers nothing for supply, and it is not legal, regulatory or customs advice. Quotes depend on what the manufacturer can supply, and an order exists only once both sides agree in writing. Devices need a CH-REP and compliant labels, and X-ray systems need an FOPH licence before installation. Clearance, regulatory checks, and FOPH steps stay with you and your Swiss partners, as we are neither an importer nor a CH-REP in Switzerland.
Without the operator's FOPH licence, the supplying firm may not install or hand over a medical X-ray system. Send the model, the site and the licence details, and we will quote with the CH-REP, the label languages and the route.
Yes. If you send a model number or specification to connect@medigear.uk, or enter it in the RFQ form on the buyer's page, you'll receive an email reply, and no account is needed. We quote for university, cantonal and private hospitals in Switzerland, dental and veterinary practices, X-ray firms, Swiss importers and distributors.
No. Medical devices go through no official authorisation in Switzerland, and Swissmedic's role is market surveillance. A device must still meet the Medical Devices Ordinance, and a maker based outside Switzerland needs a CH-REP whose name and address appear next to the CH-REP symbol on the label.
Manufacturers (or their CH-REPs) and importers register with Swissmedic before they first place a device on the Swiss market, and they report changes within one week. Swissmedic then assigns the Swiss single registration number. Distributors cannot register, and the importer's name and address go on the device or its papers.
The three official languages, with standard symbols allowed in place of words. Fewer languages, or English, are allowed only if the device goes solely to health professionals who agree, patient and user safety is assured and effective use is not put at risk. Users can ask for more information in an official language.
The operator needs an FOPH licence before the system is set up, with radiation-protection plans and shielding calculations. The licence runs for 10 years and ends when the holder changes. Firms that trade in, rent, install, or test X-ray systems in Switzerland also need their own FOPH licence.
The supplier runs an acceptance test on the whole system before handover. The operator then has constancy tests done, and an FOPH-licensed firm performs a state check after each maintenance, at least yearly for CT and mammography and every six years for standard radiography and dental units.
Usually not. A practice can buy one unit of most catalogue lines, and our first reply states any minimum the manufacturer sets. For a single X-ray unit, we also ask which FOPH-licensed firm will install and test it, because the supplier's acceptance test comes before handover.
Switzerland is landlocked, so sea freight lands at a port such as Rotterdam and travels on to the Swiss Rhine Ports at Basel, while air freight comes into Zurich. Lorries over 3.5 tonnes may not run at night or on Sundays, which shapes the last leg to your site.