In Sweden, labels and instructions for medical devices must be in Swedish when they reach users or patients, and a trader transferring X-ray units must check the recipient's SSM licence or notification. Our quotes for hospitals in Sweden cover the Swedish texts, the certificates and freight to Gothenburg or Stockholm.
In Sweden, labels and instructions for use must be in Swedish when a device reaches users or patients, under the Swedish medical device ordinance that supplements the EU device rules. Läkemedelsverket, the Swedish Medical Products Agency, can grant exemptions on a case-by-case basis. No general exception for professional users appears in the text. Medical X-ray also needs a licence from SSM, the Swedish Radiation Safety Authority. Shipped from Great Britain, a unit enters Sweden as a non-EU import, which is why the quote starts with the texts and the licence.
Hospitals, clinics, and medical device distributors can send their requests to MediGear, a medical equipment distributor registered in England and Wales; so can supply manufacturing companies in Sweden that need a unit. We work for healthcare buyers in more than 80 countries, from national healthcare systems to private clinics, handling the quote, documents, and freight. For Sweden, we ask each maker for Swedish labels and instructions, since medical equipment and supplies manufacturing stays with the makers. We send the quote once every point below is answered. This page is for buyers, not for a medical device manufacturer seeking distributor cover. The buyers page is where requests start, and it needs no account.
The 21 regions run healthcare in Sweden, and our quotes go to buyers such as:
Public buying follows the Public Procurement Act of 2016, and authorities may buy through a central purchasing body. Adda serves municipalities and regions with framework agreements. Each of the 21 regions runs its own buying, so quotes go to the region concerned. Region Västmanland is building a new emergency hospital in Västerås, with about 180 hospital beds and move-in due in 2029. Groundworks for Region Norrbotten's new hospital in Kiruna began on 2 September 2026. Even one replacement unit is worth a request.
Sweden's supplementary act and ordinance sit alongside the EU regulation, and the ordinance makes Läkemedelsverket the competent and market-surveillance authority. IVO, the Health and Social Care Inspectorate, covers devices made in-house by healthcare and implant information for patients. The language rule covers any device supplied in Sweden, whether the device is made in Sweden or abroad. The old national registration rules lapsed around 28 May 2026, once EUDAMED became mandatory, and we could not confirm whether Swedish distributors must now register.
Under Socialstyrelsen's rules, care providers must ensure devices are checked and correctly installed before use on patients. Staff check each device before use. We are the equipment supplier on the quote and act as neither importer nor distributor in Sweden. We give no regulatory advice, and the certificates behind each unit are listed in the quote.
The Radiation Protection Act of 2018 bans work with ionising radiation without a licence. That work includes using, installing and maintaining X-ray apparatus. Health care with X-ray needs an SSM licence, and the applicant must be in IVO's register of care providers. Only intraoral dental X-ray at up to 75 kV that is not handheld is notifiable; panoramic and CBCT units require a licence. Changes to the units held under a licence are notified to SSM for registration before they happen.
Before clinical use, the licence holder runs a delivery check, then function and performance checks at the intervals needed and after any intervention. A hospital physicist with at least five years' X-ray experience leads radiation physics. Since 1 September 2025, transferring X-ray equipment in the course of business has been notifiable. In Sweden, X-ray-generating devices may be transferred only to a licence holder or a notified party. The transferor must check the recipient's licence or notification and keep a register. So we ask for your SSM number before an X-ray unit ships.
The maker has to clear these points first:
Open questions go to the maker in writing before we quote, because the SSM registration and your delivery check both depend on the exact unit.
Swedish Customs, Tullverket, always needs an import declaration, filed by the importer or an agent, and the carrier may act as agent. Declarations are submitted via EDI or through its online services. Our papers for a Swedish order:
Jordbruksverket, the Swedish Board of Agriculture, applies ISPM 15 to wood packaging and dunnage from outside the EU. Packaging that fails is destroyed or heat-treated and may not be reused anywhere in the EU, all at the importer's expense. For this reason, we ask makers for heat-treated, stamped crates.
Our delivery ends at the port or airport you name, where you or your agent file the import declaration with Tullverket. The last leg to site is yours, and sites in Norrbotten and Västerbotten add a long road leg in winter conditions.
Most catalogue lines, including medical diagnostic equipment, can be quoted for one unit, such as a patient monitor for a clinic in Uppsala. For a new ward, see hospital setup, and theatre teams can browse Surgical and Therapeutic Equipment. Medical supplies that are devices, including surgical supplies, need Swedish labels and instructions too. If a unit is scientific equipment, not a medical device, say so in your request. Our refurbished range can serve Sweden, as neither the Swedish act nor its ordinance mentions used or refurbished devices. The same Swedish texts, delivery checks and SSM rules apply. For digital X-ray systems, give the model and your SSM number in the request so that the quote can cover the transfer check.
Swedish buyers can use this page to plan, but it makes no offer to supply and does not replace legal, regulatory or customs advice. Stock at the maker decides each quote, and we order nothing until both sides have signed off in writing. Swedish labels and instructions are needed for devices, and an SSM licence or notification is required for X-ray units before use. Your agent clears the goods, and the Swedish regulatory steps sit with you, because we hold no importer or distributor role in Sweden.
Since September 2025, a business transferring X-ray equipment must check that the recipient holds an SSM licence or has notified. Share that number, the model and the site, and we will quote with the Swedish texts and the route.
By email to connect@medigear.uk or through the RFQ form on the buyers page, with a model number or specification. There is no account to set up, and we reply by email. We quote for regions, university hospitals, private providers, dental and veterinary clinics, municipalities and distributors, as well as other equipment and supplies suppliers that need a unit.
Yes. Device information must be in Swedish when a device is supplied to users or patients in Sweden, even by a Swedish medical device manufacturer, and the ordinance has no general exception for professional users. Läkemedelsverket can grant individual exemptions, with conditions, so we check the manufacturer's Swedish texts before quoting.
SSM, the Swedish Radiation Safety Authority. Healthcare with X-ray needs a licence, and the applicant must be in IVO's register of care providers. Intraoral dental units at up to 75 kV that are not handheld only need notification, while panoramic and CBCT units need a licence.
Since 1 September 2025, transferring X-ray equipment in the course of business has been notifiable to SSM. The transferor must check that the recipient holds a licence or has notified SSM and keep a register of transfers, so we ask for your SSM number before an X-ray unit ships.
The licence holder runs a delivery check before clinical use, then function and performance checks at the intervals needed and after any intervention. SSM sets no fixed interval, and a hospital physicist with at least five years' X-ray experience leads radiation physics.
The importer, either directly or through an agent registered with Tullverket; the carrier can also act as agent. Declarations are submitted via EDI or Tullverket's online services, using an EU EORI number. We send the invoice, packing list, transport documents, codes and CE file.
Yes. One monitor is a normal order for us, and any minimum quantity the maker insists on is stated in the first reply. For an X-ray unit, the quote also notes the SSM steps, including the licence check before dispatch.
It can in the north. Heavy trucks need winter tyres from 10 November to 10 April, and in winter icebreakers assist only ships that meet Sjöfartsverket's traffic restrictions. Lead time also depends on the maker's stock, so allow some slack for sites in Norrbotten or Västerbotten.