Sale on Ophthalmic Equipment - Starting from 16 November!
In Singapore, an X-ray or CT unit can be sold only to someone who holds, or has applied for, an NEA licence to possess it, and each consignment needs its own import licence through TradeNet. Our quotes for Singapore start from the HSA registration and those NEA licences, then set out freight into a PSA terminal or Changi.
In Singapore, an X-ray unit, CT scanner or dental OPG may be sold or supplied only to someone licensed to possess it. Someone who has applied for that licence qualifies too. The National Environment Agency (NEA) issues the IR2 licence to keep and use a unit. Each consignment brought in also needs an IR4 import licence, filed through TradeNet. NEA expects the device to be on HSA's register first, so the documentation comes before the freight.
Registered in England and Wales, we are MediGear, a medical equipment distributor that quotes, documents and ships for healthcare buyers in more than 80 countries. Where the order is for Singapore hospital equipment and supplies, we look for verified makers whose model is on the Singapore Medical Device Register. If it is not, a local registrant named by the product owner can apply to list it. The quote then reaches your engineers and buying team with the points below settled. Our buyers page handles requests, and you do not have to open an account.
We quote for these Singapore healthcare buyers:
ALPS buys medical equipment and supplies for the public part of Singapore's healthcare system. It invites Singapore-registered companies to its sourcing events, and government agencies post tenders on GeBIZ. The new Alexandra Hospital is due to open in stages from 2028, and the Eastern General Hospital campus will have about 1,400 beds. A clinic that needs one bladder scanner can send the model and get a written quote. A group planning advanced diagnostic imaging in Singapore can send its model and get a quote in the same way.
Medical device regulation rests on the Health Products Act 2007 and its 2010 device rules, run by the Health Sciences Authority (HSA). Class B, C and D devices must be registered with HSA and listed on its register before they are supplied. Class A devices are exempt but are notified. The registrant is a local applicant named by the product owner in a letter of authorisation. A device that needs registration but has none can enter only through a Special Access Route approved by HSA.
Anyone in the Singapore medical devices industry who imports or wholesales devices, such as a medical supplies distributor, needs a dealer's licence. For Class B to D, importers and wholesalers hold GDPMDS (SS 620) certification. Alternatively, an ISO 13485 or MDSAP certificate works if its scope covers distribution of those device categories. Labels must be in English. Since we hold no Singapore registration or import/wholesale role, we give no regulatory advice, though the certificates for each unit appear in its quote.
NEA's Radiation Protection and Nuclear Science Group runs the Radiation Protection Act 2007 and the ionising radiation regulations in force since 20 February 2023. IR1 covers dealing in or selling X-ray equipment, IR2 covers keeping and using it, and IR4 covers each consignment imported. The controlled list covers diagnostic imaging devices such as medical X-ray, CT and dental OPG units, as well as bone densitometers. The licence application needs the HSA registration or approval first.
A user must hold an IR2 licence, or have applied for one, before seeking an import permit. NEA reviews floor plans and the equipment layout before the unit is first used. Each licensee names a qualified person for every unit, and radiation workers hold their own registration. New facilities are inspected before they operate; existing ones are inspected at least once a year or once every two years. NEA's guidance also expects yearly checks against the maker's specifications by trained staff from the supplier.
These come up with the maker before we quote:
Open points go to the maker in writing before we quote, since the HSA registration names the exact model, and an IR2 licence covers only the apparatus on its inventory list.
Singapore Customs expects the importer to hold a UEN from ACRA, open a customs account and appoint a declaring agent. Every permit goes through TradeNet, and for X-ray and CT, the IR4 licence is part of that permit. Air and conventional cargo must show the permit with its papers, and the documents are kept for five years. Each order arrives with:
ISPM 15 is not required for imports, says Singapore's report to the IPPC. NParks, which took over plant health from AVA in 2019, accredits treatment providers for exports. We still ask makers for heat-treated, stamped crates.
Delivery ends at the terminal or airport you nominate, where your declaring agent completes the TradeNet declaration, and the last leg is yours. Tuas Port has 14 berths in use and is on track to reach 18 by 2027. Heavy afternoon thunderstorms are common, and the Northeast Monsoon runs from December to early March.
A dental clinic that wants one OPG unit can have it quoted on most catalogue lines once it holds or applies for its IR2 licence. For a new clinic, see clinic setup, and women's health teams can browse Women, Children and Neonatal. Our refurbished range covers pre-owned units, and we found no HSA ban on refurbished medical equipment. HSA treats refurbishing as a manufacturing activity, so the refurbishing facility needs a manufacturing licence, and a refurbished device must be labelled as refurbished. NEA's licences apply to a used X-ray unit just as to a new one.
Singapore buyers should read this page as general information only: it is not an offer to supply, nor legal, regulatory or customs advice. The manufacturer's stock determines what we can quote, and we place an order only when both sides agree in writing. Devices require HSA registration and English labels, and X-ray units require NEA licences to hold and import them. Your registrant and declaring agent handle clearance and the regulatory side, since we are not a Singapore importer or licence holder.
X-ray and CT units in Singapore go only to a site that holds, or has applied for, an NEA licence to possess them, and each shipment needs an IR4 import licence. Send the model and site, and the quote covers the HSA status, the NEA steps and the route.
Directly, yes. Email connect@medigear.uk or use the RFQ form on the buyer's page; a model number or specification is enough to get started, whether you are adding diagnostic capabilities in Singapore or replacing a unit. Nobody needs to open an account. We quote for public clusters, private groups, laboratories, dental practices and licensed medical equipment suppliers in Singapore.
Class B, C and D devices must be registered and listed on the Singapore Medical Device Register before they are supplied, through a local registrant authorised by the product owner. Class A devices are exempt from registration but are notified, and an unregistered device needs an HSA-approved Special Access Route.
An IR2 licence to keep and use the unit, held or applied for before import, and an IR4 licence for each consignment through TradeNet. A local dealer that sells irradiating apparatus holds an IR1 licence, and NEA expects the device's HSA registration first.
Good Distribution Practice for Medical Devices, the SS 620 standard. A medical equipment supply firm in Singapore that imports or wholesales Class B to D devices needs GDPMDS certification to hold a dealer's licence. Alternatively, an ISO 13485 or MDSAP certificate works if its scope covers distribution of those device categories.
Yes. Smaller items can fly into Changi Airport, and sea freight goes into Tuas Port or the Pasir Panjang Terminals, which PSA runs as one facility. We deliver to the terminal or airport you nominate, and your declaring agent takes over there.
The importer or its declaring agent, after registering with ACRA for a UEN and activating a customs account. For X-ray and CT, the IR4 licence goes into the same permit, and our side supplies the invoice, packing list, transport papers, HS codes and the model's certificates.
We will. Medical imaging equipment can be quoted one unit at a time on most catalogue lines, and a maker's minimum order, where one applies, appears in our first reply. The unit still needs its HSA registration, and for X-ray, the site's NEA licence, which we confirm before quoting.
HSA counts refurbishing as manufacturing, so the refurbishing facility needs a manufacturing licence, and the device must be labelled as refurbished. NEA's licences apply to a used X-ray unit as to a new one, and the quote states the lead time and route.