In Portugal, labels and instructions for medical devices must be in Portuguese unless INFARMED grants a dispensation, and distributors notify INFARMED of the devices they supply. Our quotes for Portugal healthcare buyers check the Portuguese texts first, then set out the CE file and freight to Lisbon, Leixões or Sines.
In Portugal, Decree-Law 29/2024 implements the EU device regulation and designates INFARMED as the competent authority. Medical devices in Portugal need Portuguese labels and instructions for use. INFARMED may grant a dispensation for certain groups of devices or users, and since April 2025, this has covered the screens of devices for professional use. A unit shipped from Great Britain is also a non-EU import, so a quote for Portugal starts with the texts and the CE file.
Working as MediGear, we are a medical equipment distributor registered in England and Wales. Healthcare buyers in more than 80 countries come to us for quotes, documents and freight on medical equipment and supplies. For imaging equipment in Portugal, we look for verified makers. They must supply Portuguese labels and instructions, and the Portuguese X-ray information the law requires before delivery. We work through the points below with the maker before any quote for Portugal medical equipment and devices goes to your engineers. Use the buyers page to send a request; no account is required.
Since January 2024, the health system in Portugal has run public care through Local Health Units, and we quote for:
Public procurement contracts, including those for Portugal's healthcare infrastructure, are published on BASE, run by IMPIC, and EU-level tenders appear on TED. SPMS, the health ministry's shared-services body, acts as the central purchasing body for the SNS, the national health service, within Portugal's healthcare system. A clinic replacing a single unit of medical diagnostic equipment can start with nothing more than its model number, and the first reply says what we can quote.
Decree-Law 29/2024 makes the supply of devices for resale or for use in health services subject to notification to INFARMED. Distributors need a technical director and proper premises. They send INFARMED their device lists electronically, with labels and instructions. They also keep transaction records for five years. A hospital, or a distributor in Portugal, that brings a unit in from outside the EU should ask its own advisers who hold the importer's role.
INFARMED notifications sit with Portuguese firms, not with us, and we give no regulatory advice, but the quote does list the unit's certificates. Only firms with a quality management system, such as oN ISO 13485, may maintain, calibrate, or provide technical assistance on medical devices.
Since 1 July 2024, the Entidade Reguladora da Saúde (ERS) has handled radiation protection for medical exposures. The environment agency APA handles other practices, such as veterinary X-ray. Most medical X-ray needs a licence. Dental units, including intraoral, panoramic and CBCT, bone densitometry and veterinary units need registration. A mobile X-ray solution for a veterinary practice is registered like a fixed one, since veterinary X-ray is registered whether or not it stands at a fixed site. For medical exposure, the holder must be a healthcare provider whose site is registered with ERS where the equipment stands. Medical exposure practices are subject to prior control, and ERS authorises the practice through a registration or licence certificate.
An X-ray generator must come with information on its risks, use, testing and maintenance, written in Portuguese and supplied before delivery. The manufacturer or importer must also train the users. ERS guidance asks for acceptance tests before patient use, within a quality assurance programme. We found no national test intervals, so we send the maker's schedules with the quote. Since January 2026, intraoral dental units have had their own rules, with registration renewed every five years.
The maker answers these questions before we quote:
Open points go to the maker in writing, because the Portuguese texts and the training must be ready before the unit is delivered.
The Autoridade Tributária e Aduaneira (AT) takes import declarations through STADA Importação. Anyone entitled to present the goods may lodge one; a customs representative is optional, and an importer filing for itself must register with the AT first. Each Portuguese order travels with:
For wood packaging from outside the EU, DGAV has applied ISPM 15 since March 2005. The wood is treated, debarked and marked on each unit, and no phytosanitary certificate is needed. Conifer packaging sent from the mainland to the Azores or Madeira must also meet ISPM 15, so we ask makers for heat-treated, stamped crates.
Our delivery stops at the port or airport you name. There, you or your customs representative lodge the import declaration through STADA. The last leg is yours, including onward shipping to the Azores through Portos dos Açores or to Madeira through APRAM. Please tell us if you prefer sea or air, and the quote will follow that route.
Single-unit requests are welcome from clinics and hospitals across the healthcare system in Portugal, on most catalogue lines, such as one ultrasound unit for a clinic in Faro. For a new site, see clinic setup, and endoscopy teams can browse Gastroenterology Equipment. We found no provision on used or refurbished devices in Decree-Law 29/2024, so our refurbished range can serve Portugal. The usual rules stay: EU conformity and the CE mark when the unit first enters the EU market, Portuguese texts, servicing by certified firms and the X-ray licence or registration.
Nothing on this page is an offer to supply, and none of it is legal, regulatory or customs advice for Portuguese buyers. It is general information from the official sources we could open. The maker's supply sets what we can quote, and nothing is ordered before both sides agree in writing. Devices need Portuguese labels and instructions, and X-ray units need an ERS licence or registration before use. You and your representative handle clearance, the INFARMED notification, and the regulatory side, because we are not a Portuguese importer or distributor.
Portuguese law asks for labels and instructions in Portuguese and, for X-ray generators, Portuguese information on risks, use, testing and upkeep before delivery. Give us the model and site, and the quote will cover the texts, the CE file and the route.
Yes. A ULS, an oncology institute, a private group or a Portuguese distributor can send a model number or specification by email to connect@medigear.uk or through the RFQ form on the buyer's page.No account is required, and the answer comes back by email.
Yes. Decree-Law 29/2024 requires labels, instructions for use and promotional material in Portuguese, though other languages may be added. INFARMED can dispense Portuguese for set groups, and since April 2025 it has done so for the screens of professional-use devices. We check the maker's texts against this.
Yes. Supplying devices for resale or for use in health services depends on notification to INFARMED, and distributors send their device lists, labels and instructions through SIDM. They also need a technical director and must keep transaction records for five years.
Since July 2024, ERS has covered medical exposures and APA other practices, such as veterinary X-ray. Most medical X-ray requires a licence, while dental units, including intraoral, panoramic, and CBCT, and bone densitometry require registration. A licensed practice may start only once the licence is issued.
Information on its risks, use, testing, and maintenance, written in Portuguese and supplied before delivery, along with user training from the manufacturer or importer. ERS also expects acceptance tests before use on patients, so we send the maker's test and service schedules.
Through STADA Importação, run by the Autoridade Tributária e Aduaneira. Anyone entitled to present the goods can lodge the declaration, and a customs representative is optional. W e provide the invoice, packing list, transport document, HS codes, and the CE file.
Yes. Most catalogue lines can be quoted for a single unit, and any minimum order from the maker will be shown in our first reply. We deliver to the port or airport you name, and you arrange onward shipping to Madeira or the Azores.
Mostly the texts and papers: labels and instructions in Portuguese, the X-ray information and training, and the ERS licence or registration. Wood packaging without the ISPM 15 mark can also hold a shipment, and the quote states the lead time and route.