Post market surveillance is how regulators and manufacturers ensure medical devices remain safe after they reach the market. Here is how it works and what it means for buyers.
Getting a medical device onto the market is only the beginning. Once a device is placed on the market, the manufacturer is legally required to continue monitoring its safety and performance, collect post-market data, analyse it, and act on what they find. This is post-market surveillance — and it is now one of the most actively enforced parts of medical device regulation, particularly under the EU MDR.
This guide explains what post-market surveillance involves, what manufacturers are required to do, how it differs across markets, and what it means for buyers and healthcare organisations evaluating suppliers across the UK, EU, US, Gulf and South Africa.
Effective post-market surveillance comprises three components that work together to maintain device safety over time.
Data collection: the systematic gathering of post-market data from adverse event reports, complaints, the literature, registries, user feedback, and health technology assessments.
Analysis and action: analysis of collected data against the benefit-risk profile, with corrective actions where signals emerge — including field safety corrective actions and recalls.
Regulatory reporting through vigilance reports, periodic safety update reports and, for the EU, post-market clinical follow-up reports.
Post-market surveillance is a documented plan required under the EU MDR and equivalent frameworks, setting out which data the manufacturer will collect, from which sources, how frequently, and which thresholds will trigger action.
Post-market surveillance report for lower-risk devices, a PMS report updated at least annually, summarising findings, conclusions and any actions taken. Class IIb and III devices require a Periodic Safety Update Report.
Periodic Safety Update Report required for Class IIb and Class III devices under EU MDR; the PSUR analyses the benefit-risk balance in light of post-market data and concludes whether the technical file needs updating. In In
Post-Market Clinical Follow-Up, where clinical evaluation relies on pre-market data, may require PMCF studies or registry participation to generate ongoing real-world clinical evidence. Manufacturers of serious-incident-reporting devices must report serious incidents — where a device caused or contributed to serious injury or death — to regulators within defined timelines, typically 10 to 15 days. For
Field Safety Corrective Actions (FSCA): When PMS identifies a safety signal requiring action, the manufacturer must issue an FSCA and a Field Safety Notice, notifying regulators and customers of the required action.
Under the EU MDR, manufacturers must report statistically significant increases in non-serious incidents or expected side effects that could affect the benefit-risk balance.
Technical file update: PMS findings that affect the risk management file, clinical evaluation or benefit-risk assessment must be incorporated into the technical file — it is a living document, not a one-time submission.
Device market surveillance reporting increases with the increase in the number of devices.
|
Class |
PMS report |
PSUR required? |
PMCF required? |
|
Class I |
PMS report — annually |
No |
If clinical data are needed |
|
Class IIa |
PMS report — annually |
No |
If clinical data are needed |
|
Class IIb |
PSUR — at least every 2 years |
Yes |
Often required |
|
Class III |
PSUR — at least annually |
Yes |
Usually required |
For IVDs, equivalent requirements apply under the EU IVDR. Timelines and formats are set out in EU MDR and IVDR implementing regulations and MDCG guidance documents.
Want to check a manufacturer's PMS practices?
We work with manufacturers who maintain active PMS programmes and can request PMS summaries as part of supplier qualification. Tell us the device and market — we will ask the right questions on your behalf.
No pressure, no obligation. → Talk to the team
Post-market surveillance is primarily a manufacturer's obligation, but it has direct implications for procurement decisions.
PMS is evidence of supplier credibility. A manufacturer that demonstrates an active PMS programme — what data they collect, how they analyse it, and what actions they have taken — is a more credible supplier than one that cannot.
PMS findings can affect device safety. If PMS identifies a safety signal, the manufacturer may issue a field safety notice or update the IFU. Buyers need processes to receive these communications promptly.
PMCF data strengthens clinical confidence for devices where pre-market clinical evidence was limited; ongoing PMCF studies that build real-world evidence give buyers and clinicians greater confidence in performance.
The absence of PMS is a procurement risk; a manufacturer with no evidence of post-market surveillance is either non-compliant with regulatory requirements or failing to monitor real-world performance — both are serious concerns.
During supplier qualification, add PMS questions to the standard checklist: what is the PMS plan, when was the last PSUR or PMS report prepared, and have there been safety signals or corrective actions in the past three years?
Use these questions when evaluating a medical device manufacturer's post-market surveillance practices.
Does the manufacturer have a documented PMS plan? A "yes" with evidence — the plan or summary — is a good sign. A manufacturer who does not know what a PMS plan is fails to meet basic regulatory requirements.
When was the last PMS report or PSUR prepared? Confirm the report is recent and that the device has active surveillance. Outdated or absent reports are a concern, particularly for higher-risk devices.
Have there been safety signals or corrective actions in the past three years? An honest, documented answer is more reassuring than a claim of no issues at all. Active PMS programmes always find something to act on.
Is the manufacturer registered in EUDAMED? For EU devices, EUDAMED registration is increasingly mandatory. Registration demonstrates regulatory engagement.
How does the manufacturer communicate field safety notices to customers? Confirm the process for notification. Register your contact details with the manufacturer or distributor to ensure you are on the FSN notification list.
Is PMCF data being collected for this device? For devices with limited pre-market clinical evidence, ask whether PMCF studies are in progress and when results are expected.
Post-market surveillance is not a box-ticking exercise — it is the mechanism by which safety signals are detected and acted on before they cause harm. Suppliers who engage openly with PMS questions are generally safer partners.
These are the PMS failures most commonly identified in regulatory inspections and enforcement actions.
No documented PMS plan; a manufacturer without a documented PMS plan breaches the EU MDR, UK MDR, and equivalent requirements. It also indicates that post-market data is not being systematically collected.
PMS is treated as a complaint; complaint handling is one PMS data source, whereas true PMS draws on the literature, registries, clinical feedback, and health technology assessments. Complaint handling alone is insufficient.
Delayed reporting of serious incidents outside required timelines is one of the most frequently cited PMS enforcement failures. Manufacturers must report within strict timeframes.
Outdated technical files, PMS findings that should update the technical file — new risk data, revised clinical evidence — often do not find their way back into the documentation.
Manufacturers not providing PSURs when required; the PSUR requirement for Class IIb and Class III devices is strictly enforced. Manufacturers who cannot produce a current PSUR on request are in breach.
Post-market surveillance requirements are most detailed in the EU, but all major markets now have PMS obligations.
|
Region |
Regulator |
PMS requirement |
|
United Kingdom |
UK MDR 2002 PMS obligations; MHRA vigilance reporting; serious incident reports |
|
|
European Union |
EU MDR PMS plan, PMS report, PSUR, PMCF — most detailed globally |
|
|
United States |
FDA MDR adverse event reporting; 21 CFR Part 803; post-approval studies for PMA |
|
|
Gulf (GCC) |
SFDA & GCC bodies |
SFDA requires PMS and vigilance reporting for registered devices |
|
South Africa |
SAHPRA PMS obligations under the Medicines Act; incident reporting |
The EU MDR has set the global benchmark for PMS requirements. Manufacturers selling into the EU typically have the most structured PMS programmes, which benefits buyers in all markets.
Buyers — source medical equipment from manufacturers with active post-market surveillance programmes.
Suppliers — list your devices and demonstrate your post-market surveillance credentials to buyers.
Advertise — promote your products and services to a clinical audience.
Business overview — explore everything MediGear offers healthcare organisations.
This article is for general information only and does not constitute legal, regulatory, procurement or clinical advice. Post-market surveillance requirements, reporting timelines and enforcement policies change over time and vary by device class, country and regulatory framework. Always verify current requirements with the relevant regulatory authority and consult a qualified regulatory affairs professional for advice specific to your device and organisation. medigear.UK accepts no liability for actions taken based on this content.
We supply medical equipment from manufacturers who maintain active post market surveillance programmes. Tell us the device and market — we will confirm the PMS and vigilance reporting arrangements.
Post-market surveillance is the manufacturer's ongoing programme of collecting, reviewing and analysing data on the safety and performance of their devices once they are on the market. It covers adverse event reports, complaints, literature reviews, clinical registry data and user feedback. Under EU MDR and other regulations, it is a legal obligation and a core element of the device's compliance lifecycle.
A Periodic Safety Update Report is required under EU MDR for Class IIb and Class III devices. It analyses the current benefit-risk balance in light of post-market data, reviews safety and performance trends, and concludes whether the technical file, risk management file or clinical evaluation needs updating. Class IIb devices need a PSUR at least every two years; Class III at least annually.
PMCF is the active collection of clinical data from a device already on the market, used to supplement or update the pre-market clinical evidence. It can involve clinical investigations, participation in registries, or structured follow-up of existing users. PMCF is required when pre-market clinical data are limited or when open clinical questions can only be answered through real-world use.
A serious incident is one where a device has caused or could cause the death or serious deterioration in the health of a patient, user or other person. Under the EU MDR and other frameworks, manufacturers must report serious incidents to the national authority within defined timelines—typically 15 days for a serious public health threat and 10 days for a death or serious deterioration.
During supplier qualification, ask for the PMS plan or summary, the date of the most recent PMS report or PSUR, whether any safety signals or corrective actions have occurred in the past three years, and how customers are notified of field safety notices. A manufacturer with a genuine PMS programme will answer these questions clearly and with evidence.
Yes. If PMS identifies a safety signal after you have purchased and deployed a device, it may result in a field safety corrective action, a recall, or an updated IFU that affects how you can use the device. Registering with the manufacturer or distributor to receive FSNs and monitoring MHRA, FDA, and other regulatory alert databases keep you informed of any PMS-driven safety actions.